Heim
Über uns
Produkte
Herunterladen
Technische Lib
Kontakt
Anfrage
Sitemap
Links
 

Alarm u. Audio u. Elektronisches Kabe

Belden gleichwertige Kabel

Koaxial-Kabel

SteuerKabel

LWL Kabel

Flexible Kabel

Instrumentation Kabel

Lan Kabel
EnergieKabel
Bahn-Kabel

Robotik

Rolling Stock Kabel
Gummi u. Kran Kabel
Sicherheit Kabel

Telefon Kabel

Flughafen Kabel

Bus-Kabel

Kabelverschraubungen

Daten Kabel

Heat Detection Kabel
Hochtemperatur-Kabel
Highway Kabel
Marine, Öl, Gas & Petrochemie-Kabel
Special Kabel
Spiralkabel
Thermoelement-Kabel
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Telefon Kabel

 Drop Wires No. 12, 10B, CAD55M & 10 to CW 1406, CW 1411,CW 1417 & CW 1378

Anwendung

The drop wires are designed for use in local area network to link between pole and building or two buildings. The high tensile steel strength member wires are incorporated inside the cable to provide support. The cables can be used for crossing high voltage cables up to 11kV.

Standards

• CW 1406 (Drop Wires No.12 1 pair)

• CW 1411 (Drop Wires No.10B 2 pairs)

• CW 1417 (Drop Wires CAD55M 4 pairs)

• CW 1378 (Drop Wires No.10 2 pairs)

Bau

Dirigenten
Solid annealed bare copper of 0.5/0.9mm as per class 1 of BS 6360/IEC 60228

Isolierung
Solid low or medium density Polyethylene (CW 1406, CW 1411 & CW 1417) or Polyvinyl Chloride (CW 1378) to BS 7878

Core Wrapping
23 micron Polyester Tape

Strength Member
1 Pair: 1 element of 3 x 0.41mm brass coated steel strength member; PVC insulated to 1.4mm
2 & 4 Pairs: 3 elements of 3 x 0.25mm brass coated steel strength member; PVC insulated to 1.0mm

Mantel
Black medium density polyethylene as per BS 7878

Ripcord
Nylon

Elektrische Eigenschaften

Nominal Conductor Diameter

mm

0.9

0.5

0.5

0.5

BT Drop Wire Reference

 

No.12

No.10

No.10B

CAD55M

Standard

 

CW 1406

CW 1378

CW 1411

CW 1417

Number of Pairs

 

1

2

2

4

Maximum Conductor Resistance @20°C

Ω/km

28

95

95

95

Minimum Insulation Resistance @500V DC

MΩ.km

10000

100

10000

10000

Breaking Load

N

1350-1550

1350-1550

1350-1550

1350-1550

Maximum Mutual Capacitance @0.8KHz-3.0KHz

nF/km

-

100

56

56

Maximum Capacitance Unbalance pair-to-pair

pF/500m

-

500

275

300

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter

Color Code

CW 1406 Pair 1: Orange/White  
CW 1411 Pair 1: Orange/White Pair 2: Green/Black
CW 1417 Pair 1: Orange/White Pair 2: Red/Grey
                Pair 3: Blue/Brown Pair 4: Green/Black
CW 1378 Pair 1: Orange/White Pair 2: Green/Black

 

 

 

Abmessungen und Gewicht

Kabel-Code Anzahl der Paare Isoliermaterial
Nominal Isolationsdicke
mm
Minimale Dicke Mantel
mm
Min/Max Overall
Diameter
mm
Nenngewicht
kg/km
0.5mm Conductor

TP1411-2Y2Y-2P05-DW10B

2

PE

0.2

0.4

5.1/5.6

32

TP1417-2Y2Y-4P05-DW55M

4

PE

0.2

0.5

5.3/5.5

35

TP1378-Y2Y-2P05-DW10

2

PVC

0.2

0.4

5.3/5.5

33

0.9mm Conductor
TP1406-2Y2Y-1P09-DW12 1 PE 0.3 0.5 5.0/5.5 32